Blower Door Test · Nairne, Adelaide Hills

Blower Door Test — Nairne, Adelaide Hills

Project overview

A pre-renovation airtightness test on an existing home at Nairne in the Adelaide Hills, ahead of a planned extension. We set up a Retrotec blower door to measure how leaky the existing building fabric is — establishing a baseline before the works so air-sealing can be targeted where it matters most.

12.5 ACH

Air changes @ 50 Pa

1,149 cm² · 0.115 m²

Equivalent leakage area

≈ 38 cm across

Equivalent round hole

Blower Door TestingAirtightnessPre-Renovation

Outcome

Baseline result: 12.5 ACH @ 50 Pa — equivalent to a 1,149 cm² (0.115 m²) hole in the building fabric, about a 38 cm round opening. A clear, measurable target to seal against during the extension.